{"id":103538,"date":"2010-09-09T00:00:00","date_gmt":"2010-09-09T00:00:00","guid":{"rendered":"https:\/\/www.deberes.net\/tesis\/sin-categoria\/sistemas-tomograficos-multimodalidad-para-animales-de-laboratorio\/"},"modified":"2010-09-09T00:00:00","modified_gmt":"2010-09-09T00:00:00","slug":"sistemas-tomograficos-multimodalidad-para-animales-de-laboratorio","status":"publish","type":"post","link":"https:\/\/www.deberes.net\/tesis\/medicina-nuclear\/sistemas-tomograficos-multimodalidad-para-animales-de-laboratorio\/","title":{"rendered":"Sistemas tomogr\u00e1ficos multimodalidad para animales de laboratorio"},"content":{"rendered":"<h2>Tesis doctoral de <strong> Eduardo Lage Negro <\/strong><\/h2>\n<p>Esta tesis doctoral explora alternativas tecnol\u00f3gicas para la implementaci\u00f3n de sistemas pet y spect para roedores as\u00ed como la integraci\u00f3n de los mismos con sistemas tomogr\u00e1ficos de rayos x. Espec\u00edficamente, se aborda el problema de optimizar el rendimiento de los esc\u00e1neres basados en anillos parciales de detectores debido a que, aunque son una soluci\u00f3n mucho menos costosa que los equipos basados en anillos completos, las implementaciones realizadas tienen prestaciones comparativamente pobres. Para la implementaci\u00f3n de un sistema multimodalidad, los sistemas de imagen funcional basados en anillos parciales de detectores presentan la posibilidad de incluir un sistema de imagen anat\u00f3mica coplanar en el mismo anillo rotatorio facilitando, de esta forma, la calibraci\u00f3n geom\u00e9trica de la m\u00e1quina y la fusi\u00f3n de las im\u00e1genes de ambas modalidades.    los sistemas de imagen funcional propuestos se basan en bloques detectores de elevada resoluci\u00f3n intr\u00ednseca y \u00e1rea activa reducida cuyo dise\u00f1o permite que funcionen con cambios m\u00ednimos tanto en pet como en spect. Para la detecci\u00f3n y digitalizaci\u00f3n de los datos de los detectores se ha desarrollado una nueva t\u00e9cnica digital denominada wmlet (width-modulated leading-edge timing) y se ha implementado una arquitectura de adquisici\u00f3n de datos sobre dispositivos de l\u00f3gica programable basada en la misma. El rendimiento y las posibilidades de esta aproximaci\u00f3n se han evaluado mediante la construcci\u00f3n de un prototipo de sistema de adquisici\u00f3n de datos, v\u00e1lido para pet y spect, y la realizaci\u00f3n de pruebas exhaustivas del mismo utilizando diferentes tipos de detectores.     para evaluar la aplicabilidad de la combinaci\u00f3n tecnol\u00f3gica propuesta a la construcci\u00f3n de equipos de imagen tomogr\u00e1fica se han implementado sistemas pet y spect para roedores cuyo dise\u00f1o permite incluir un sistema ct de rayos x coplanar a los mismos. El rendimiento del sistema pet  presentado se ha evaluado mediante el est\u00e1ndar nema nu-4, recientemente aprobado para la evaluaci\u00f3n del rendimiento de tom\u00f3grafos pet de animales de laboratorio. Para caracterizar el sistema spect implementado en este trabajo, y debido a la no existencia de un protocolo est\u00e1ndar para sistemas de animales peque\u00f1os, se ha seguido un protocolo similar al utilizado para sistemas de humanos y se han realizado estudios in vivo con roedores y con maniqu\u00edes. Para validar la aproximaci\u00f3n multimodalidad basada en sistemas coplanares se ha integrado un sistema tomogr\u00e1fico de rayos x con el sistema pet, se ha medido la precisi\u00f3n del alineamiento entre ambas modalidades y se han realizado estudios multimodalidad con maniqu\u00edes y con roedores (in vivo). En relaci\u00f3n al sistema ct se incluyen las aportaciones realizadas al dise\u00f1o e implementaci\u00f3n del mismo.     para finalizar, se compara el rendimiento y el potencial de las aproximaciones de dise\u00f1o propuestas con otras desarrolladas por diversos grupos de investigaci\u00f3n, algunas utilizadas en  sistemas comerciales, demostrando su viabilidad para la implementaci\u00f3n de sistemas de peque\u00f1o animal.<\/p>\n<p>&nbsp;<\/p>\n<h3>Datos acad\u00e9micos de la tesis doctoral \u00ab<strong>Sistemas tomogr\u00e1ficos multimodalidad para animales de laboratorio<\/strong>\u00ab<\/h3>\n<ul>\n<li><strong>T\u00edtulo de la tesis:<\/strong>\u00a0 Sistemas tomogr\u00e1ficos multimodalidad para animales de laboratorio <\/li>\n<li><strong>Autor:<\/strong>\u00a0 Eduardo Lage Negro <\/li>\n<li><strong>Universidad:<\/strong>\u00a0 Polit\u00e9cnica de Madrid<\/li>\n<li><strong>Fecha de lectura de la tesis:<\/strong>\u00a0 09\/09\/2010<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3>Direcci\u00f3n y tribunal<\/h3>\n<ul>\n<li><strong>Director de la tesis<\/strong>\n<ul>\n<li>Juan  Jos\u00e9 Vaquero L\u00f3pez<\/li>\n<\/ul>\n<\/li>\n<li><strong>Tribunal<\/strong>\n<ul>\n<li>Presidente del tribunal: andres Santos lleo <\/li>\n<li>dom\u00e9nec Ros puig (vocal)<\/li>\n<li>Jos\u00e9 Manuel P\u00e9rez  morales (vocal)<\/li>\n<li>Jos\u00e9 Udias (vocal)<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Tesis doctoral de Eduardo Lage Negro Esta tesis doctoral explora alternativas tecnol\u00f3gicas para la implementaci\u00f3n de sistemas pet y spect [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[209607,9343,16008,15990],"tags":[16427,121475,209608,127276,209609,31000],"class_list":["post-103538","post","type-post","status-publish","format-standard","hentry","category-maquinaria-nuclear","category-medicina-nuclear","category-politecnica-de-madrid","category-tecnologia-nuclear","tag-andres-santos-lleo","tag-domenec-ros-puig","tag-eduardo-lage-negro","tag-jose-manuel-perez-morales","tag-jose-udias","tag-juan-jose-vaquero-lopez"],"_links":{"self":[{"href":"https:\/\/www.deberes.net\/tesis\/wp-json\/wp\/v2\/posts\/103538","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deberes.net\/tesis\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.deberes.net\/tesis\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.deberes.net\/tesis\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deberes.net\/tesis\/wp-json\/wp\/v2\/comments?post=103538"}],"version-history":[{"count":0,"href":"https:\/\/www.deberes.net\/tesis\/wp-json\/wp\/v2\/posts\/103538\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.deberes.net\/tesis\/wp-json\/wp\/v2\/media?parent=103538"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.deberes.net\/tesis\/wp-json\/wp\/v2\/categories?post=103538"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.deberes.net\/tesis\/wp-json\/wp\/v2\/tags?post=103538"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}