{"id":109107,"date":"2018-03-11T10:34:16","date_gmt":"2018-03-11T10:34:16","guid":{"rendered":"https:\/\/www.deberes.net\/tesis\/sin-categoria\/wireless-implantable-bioimpedance-measurement-system-for-myocardial-regeneration-monitoring\/"},"modified":"2018-03-11T10:34:16","modified_gmt":"2018-03-11T10:34:16","slug":"wireless-implantable-bioimpedance-measurement-system-for-myocardial-regeneration-monitoring","status":"publish","type":"post","link":"https:\/\/www.deberes.net\/tesis\/electronica\/wireless-implantable-bioimpedance-measurement-system-for-myocardial-regeneration-monitoring\/","title":{"rendered":"Wireless implantable bioimpedance measurement system for myocardial regeneration monitoring"},"content":{"rendered":"<h2>Tesis doctoral de <strong> Francisco Bogonez Franco <\/strong><\/h2>\n<p>La bioimpedancia es una t\u00e9cnica inocua, no invasiva y no destructiva que ha demostrado su val\u00eda en el diagn\u00f3stico y monitorizaci\u00f3n en una amplia variedad de procesos biol\u00f3gicos. El objetivo principal de esta tesis es el dise\u00f1o e implementaci\u00f3n de un sistema capaz de monitorizar un tejido implantado para la regeneraci\u00f3n cardiaca. Dicho sistema ha sido especificado, dise\u00f1ado y construido. El monitor de bioimpedancia dise\u00f1ado tiene unas dimensiones reducidas de 35 x 35 x 10 mm y pesa 52 grs. La autonom\u00eda es de 30 d\u00edas y utiliza el protocolo zigbee para realizar la comunicaci\u00f3n entre el monitor de bioimpedancia y el pc. Realiza la medida en 14 frecuencias desde 100 hz hasta 200 khz, almacenando la informaci\u00f3n medida en una memoria flash interna. el monitor de bioimpedancia ha sido dise\u00f1ado para la monitorizaci\u00f3n de la regeneraci\u00f3n tisular usando c\u00e9lulas madre. La aplicaci\u00f3n final de este monitor de bioimpedancia es el de supervisar la recuperaci\u00f3n en tejido card\u00edaco da\u00f1ado cuando se realice una reconstrucci\u00f3n basada en el implante de c\u00e9lulas madre. En el momento de acabar esta tesis doctoral el parche de c\u00e9lulas madre a\u00fan no estaba disponible. A pesar de ello, la viabilidad del sistema fue validada sobre medidas en tejido card\u00edaco. Otras aplicaciones pueden beneficiarse de este peque\u00f1o dispositivo implantable, incluyendo aplicaciones no implantables, como monitorizaci\u00f3n de rechazo de \u00f3rganos en transplantes, monitorizaci\u00f3n de fluidos corporales en pacientes en hemodi\u00e1lisis, astronautas, pilotos de f1, etc. Con ligeras modificaciones se puede emplear en la monitorizaci\u00f3n de infarto cerebral. antes del desarrollo del monitor de bioimpedancia dise\u00f1ado en esta tesis doctoral, se realiz\u00f3 un trabajo previo en el an\u00e1lisis de estructuras avanzadas de front-ends basadas en current-conveyor de segunda generaci\u00f3n y en amplificadores diferenciales de diferencias (dda) y su comportamiento respecto a la temperatura. Tambi\u00e9n se realiz\u00f3 el dise\u00f1o de un sistema de medida de bioimpedancia para monitorizar el estado de los flu\u00eddos corporales en pacientes en hemodi\u00e1lisis. El sistema dise\u00f1ado pose\u00eda unas dimensiones reducidas, 60 x 60 x 25 mm, un peso de 75 grs y realizaba la medida de bioimpedancia a 9 frecuencias cada 10 minutos. Su autonom\u00eda era de 18 horas y las comunicaciones entre el sistema y el pc era mediante el protocolo rs-485. Posteriormente a este sistema, se dise\u00f1\u00f3 un nuevo monitor de bioimpedancia cuyas dimensiones eran inferiores a las del sistema descrito con anterioridad, en concreto 40 x 40 x 10 mm. Pose\u00eda mayor autonom\u00eda, 27 d\u00edas, y con comunicaci\u00f3n inal\u00e1mbrica. Este monitor fue dise\u00f1ado para monitorizar el rechazo en el transplante de ri\u00f1\u00f3n. Realizaba la medida de bioimpedancia a 16 frecuencias cada 5 minutos. La comunicaci\u00f3n entre el sistema y el pc era mediante el uso de la banda ism de 434 mhz. el sistema final, que debe ser capaz de monitorizar tejido implantado para la regeneraci\u00f3n cardiaca supera las caracter\u00edsticas de los desarrollos previos.<\/p>\n<p>&nbsp;<\/p>\n<h3>Datos acad\u00e9micos de la tesis doctoral \u00ab<strong>Wireless implantable bioimpedance measurement system for myocardial regeneration monitoring<\/strong>\u00ab<\/h3>\n<ul>\n<li><strong>T\u00edtulo de la tesis:<\/strong>\u00a0 Wireless implantable bioimpedance measurement system for myocardial regeneration monitoring <\/li>\n<li><strong>Autor:<\/strong>\u00a0 Francisco Bogonez Franco <\/li>\n<li><strong>Universidad:<\/strong>\u00a0 Polit\u00e9cnica de catalunya<\/li>\n<li><strong>Fecha de lectura de la tesis:<\/strong>\u00a0 14\/06\/2011<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3>Direcci\u00f3n y tribunal<\/h3>\n<ul>\n<li><strong>Director de la tesis<\/strong>\n<ul>\n<li>Ramon Bragos Bardia<\/li>\n<\/ul>\n<\/li>\n<li><strong>Tribunal<\/strong>\n<ul>\n<li>Presidente del tribunal: francesc xavier Rosell ferre <\/li>\n<li>antoni Bay\u00e9s genis (vocal)<\/li>\n<li>  (vocal)<\/li>\n<li>  (vocal)<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Tesis doctoral de Francisco Bogonez Franco La bioimpedancia es una t\u00e9cnica inocua, no invasiva y no destructiva que ha demostrado [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[2675,29829,2771,15596],"tags":[104980,218399,218398,49876],"class_list":["post-109107","post","type-post","status-publish","format-standard","hentry","category-electronica","category-espectroscopia-optica","category-instrumentos-medicos","category-politecnica-de-catalunya","tag-antoni-bayes-genis","tag-francesc-xavier-rosell-ferre","tag-francisco-bogonez-franco","tag-ramon-bragos-bardia"],"_links":{"self":[{"href":"https:\/\/www.deberes.net\/tesis\/wp-json\/wp\/v2\/posts\/109107","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deberes.net\/tesis\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.deberes.net\/tesis\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.deberes.net\/tesis\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deberes.net\/tesis\/wp-json\/wp\/v2\/comments?post=109107"}],"version-history":[{"count":0,"href":"https:\/\/www.deberes.net\/tesis\/wp-json\/wp\/v2\/posts\/109107\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.deberes.net\/tesis\/wp-json\/wp\/v2\/media?parent=109107"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.deberes.net\/tesis\/wp-json\/wp\/v2\/categories?post=109107"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.deberes.net\/tesis\/wp-json\/wp\/v2\/tags?post=109107"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}